Step 7. Re-assembling the AC Drive (XRKWM only)
1. Plug the Keypad Interface Module (KIM) fabricated in the previous step into the inverter, as it was originally
(see Step 2, #4).
2. Fasten the KIM with the two (2) M4 x 10 screws removed in Step 2, limiting torque to 12 in-lb. maximum.
3. Make sure that all cabling is routed so that it is not pinched in the assembly. The multi-conductor must be
routed through an unused conduit entry. Be sure to use the appropriate conduit fittings for your environment.
4. When you re-install the cover (required for NEMA 4X / IP66 integrity), limit the installation torque on the four
(4) screws to 26 in-lb. maximum.
Figure 7: Re-assembling the AC Drive (XRKWM Option)